{"product_id":"nauticam-m16-vacuum-valve-ii-with-pushbutton-release-25625","title":"Nauticam M16 Vacuum Valve II with Pushbutton Release #25625","description":"\u003ch2\u003eM16 Vacuum Valve II (Pushbutton Release)\u003c\/h2\u003e\n\u003cp\u003eEach Vacuum Valve comes with the required Nauticam Hand Pump\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInstalling vacuum valve to housing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003ePress the red button to release pressure. Remove the plug of the M16 accessory port from the housing. Remove the cap from the vacuum valve. Tighten the vacuum valve to the housing with the tool provided.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: Slightly lubricate the O-ring with Nauticam lubricant. \u003c\/em\u003e\u003c\/p\u003e\n\u003cdiv class=\"uk-overflow-container\"\u003e\n\u003cdiv class=\"rte__table-wrapper\"\u003e\u003cspan\u003e\u003cstrong\u003eBuilding Up Vacuum\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eRemove the cap of the vacuum valve. Connect the hand pump to the valve and pump several times until it reaches the target vacuum level. The LED light will turn flashing yellow while vacuum is building up, then steady green when the target vacuum level is reached.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eAttention: After the target vacuum is reached, i.e. steady green light, attach the cap back to the vacuum valve\u003c\/em\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is recommended to leave the housing for at least 20mins to ensure it is sealed. If the LED light changes from steady green light to rapidly flashing yellow light, that means there is a leakage and please check every O-ring and conduct the vacuum test again.\u003c\/p\u003e\n\u003cp\u003ePlease ensure that the cap is attached back to the vacuum valve before going underwater.\u003c\/p\u003e\n\u003cp\u003eVacuum can be released by pushing the red release button.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eAttention: Please DO NOT attempt to go over the designated vacuum level, i.e. stop pumping when the LED turn green. Excessive vacuum level may lead to the malfunction of the camera and lens.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: Although the vacuum indicator is designated to compensate for a certain amount of temperature variation, it is recommended to conduct the vacuum test in an environment where the temperature is stable.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAfter set up, the meaning of the LED indicator in the housing:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"rte__table-wrapper\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"169\"\u003e\u003cspan\u003e\u003cem\u003eLED indicator\u003c\/em\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"426\"\u003e\u003cspan\u003e\u003cem\u003eStatus\u003c\/em\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"169\"\u003eFlashing “Blue” light\u003c\/td\u003e\n\u003ctd width=\"426\"\u003eStandby mode. The moisture alarm is active, and the system is ready for vacuum indication whenever a vacuum is detected.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"169\"\u003eFlashing “Red” light with beeping sound\u003c\/td\u003e\n\u003ctd width=\"426\"\u003eMoisture is detected.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"169\"\u003eFlashing “Yellow” light\u003c\/td\u003e\n\u003ctd width=\"426\"\u003eSome vacuum is detected, target vacuum level is not reached.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"169\"\u003eSteady “Green” light\u003c\/td\u003e\n\u003ctd width=\"426\"\u003eTarget vacuum level is reached.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"169\"\u003eRapidly flashing “Yellow” light\u003c\/td\u003e\n\u003ctd width=\"426\"\u003eVacuum is dropping. (Will occur only after target vacuum level is reached)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"169\"\u003eRapidly flashing “Red” light\u003c\/td\u003e\n\u003ctd width=\"426\"\u003eVacuum is totally lost. Circuit stalled until switched off. (Will occur only after target vacuum level is reached)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003cp class=\"bolded\"\u003eTECHNICAL SPECIFICATIONS\u003c\/p\u003e\n\u003cdiv class=\"rte__table-wrapper\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth Rating\u003c\/td\u003e\n\u003ctd\u003e150m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Nauticam","offers":[{"title":"Default Title","offer_id":58023842808195,"sku":"UWV-N25625","price":181.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/4326\/2432\/files\/nauticam-nauticam-m16-vacuum-valve-ii-with-pushbutton-release-25625-vacuum-system-variant-sku-3197178.webp?v=1778577370","url":"https:\/\/www.lightbalance.co.uk\/products\/nauticam-m16-vacuum-valve-ii-with-pushbutton-release-25625","provider":"LightBalance Underwater Imaging","version":"1.0","type":"link"}